ACT-0073 Split-Core Current Transformer

£231.00

1000 Aac input : 5 Amp output. 73MM by 62 mm opening

Description

ACT-0073 Split-Core Current Transformer

Current Sensor with 5 Amp Output

The ACT-0073 Split-core Current Transformer with input rating of 500 – 1000 Amps. It outputs a corresponding 5A output. This split-core transformer is made with high quality nickel lamination’s. Split-core transformers are ideal for installation on existing electrical wiring by snapping around the conductor. The ACT-0073 has a self-locking mechanism.

Frequent Applications

  • Power meter
  • Switchgear
  • Distributed measurement systems
  • General Sets
  • Control panels

Features

● Input up to 1,000 Amps
● Output 5A at rated current
● Accuracy at 5% to 120% of rated current at frequency of 50 Hz to 60 Hz
● UL Registered, CE and RoHS compliant
● 6 FT, 18 AWG leads

Description

“The Magnelab ACT-0073 was previously marketed as the MAG-J73C005. It is a split core current transformer that has a 500 Amp to 1,000 Amp input rating. The output on this AC current sensoris 5 Amp and it is constructed using high quality nickel lamination. Split core transformers like this one are perfect to be installed on wires that have already been installed. It easily and readily clips on around the conductor thanks to the self-locking mechanism. The AC current transformer can be used on switch gears, power meters, general sets, distributed measurement systems and control panels.

The ACT-0073 comes with up to Class 0.5 accuracy for up to 2.5VA and a Class 1 accuracy for up to 10VA. The system voltage is 720 V or 0.72 kV. It can withstand overload of 1.2 the rated current, on a continuous basis. The operating temperature range is between -20 and 70 degrees Celsius. Test voltage is 3 kV for a duration of one minute and the frequency range is between 50 Hz and 60 Hz. It is fully compliant will all necessary regulations.

Alternatively, there is the ACT-0140 AC Split-Core Current Sensor. This split core current transformer was previously sold as MAG-J141C005. The input rating is between 1,500 Amp and 2,400 Amp, with a corresponding 5 Amp output. It is also made using nickel lamination and can also be installed by easily clipping it around the existing conductor thanks to the self-locking mechanism.

The Act-0140’s accuracy is up to Class 0.5 at 1.0 VA and it has a 720 V system voltage. It has many of the same features as the ACT-0073, particularly in terms of overload withstand, operating, temperature range, test voltage and frequency range.”

Additional information

Weight 0.226796185 kg
Amp Rating

, ,

Features

Accuracy up to Class 0.5
System Voltage: 720V (0.72kV)
Overload Withstand: 1.2 times rated current continuously
Operating Temperature Range: -20°C to 70°C
Test Voltage: 3kV for 1 minute
Frequency Range: 50/60 Hz

Custom Field 2

For Quantity Discount

Input

AC

Output

5A

Product Type

Split Core CT's

Reviews

There are no reviews yet.

Be the first to review “ACT-0073 Split-Core Current Transformer”