Home > Current Sensors & Transducers
A description of the various subcategories is available at the bottom of this page. You may choose a subcategory above to filter the results shown below.
Sort By:
Page of 2
Wireless SCT-200W Magnelab Split-Core Sensor RCT-1800-000 Current Sensor
70-800 Aac input : 333 mVac output. 1.25" opening 100-1500 Aac input : 333 mVac output. 2.0" opening 250-5000 Aac input : 70 mVac output for every 1000A. 6" diameter opening. Flexible
SCT-0750 Magnelab Split-Core AC Current Sensor SCT-1250 Split-Core AC Current Sensor RCT-1800 Magnelab RopeCT AC Current Sensor
5-200 Aac input : 333 mVac Output. 0.75" opening
50-800 Aac input : 333 mVac output. 1.25" opening 250-5000 Aac input : 333 mVac output. 6" opening. Flexible
Magnelab 3-Phase RopeCT AC Current Sensor Magnelab Three-Phase AC Current Transducer Magnelab Rev Grade AC Sensor SCT-075R
3-Phase 250-5000 Aac input : 333 mVac output. 6" opening. Flexible 3-phase 250-5000 Aac input : 4-20 mA output. 6" opening. Flexible.
50-250 Aac input : 333 mVac output. 0.75" opening. +/- 0.5% linearity, phase angle +/- 0.25%
ICT-2000 Magnelab Split-Core Output Transformer Magnelab Solid-Core AC Current Sensor UCT-0750 ACT-0024 Magnelab Split-Core AC Current Output Transformer
400 to 1,600A input : 5A output, 2.0" Opening 30-100 Aac input : 333 mVac output. 0.3" opening
100 to 300 Aac Input : 5 Aac output. 24mm Opening
Magnelab Split-Core AC Transformer ACT-0036 Magnelab Split-Core Transducer DCT-0016-100 Magnelab Split Core AC Current Sensor SCT-0400
200-400 Aac Input: 5 Aac output. 36mm opening 100 Aac input : 5 Vdc output. 16mm Opening
1-75 Aac input : 333 mVac output. 0.4" opening
SCT-2000 Magnelab Split-Core AC Current Sensor SCT-3000 Magnelab Split-Core AC Current Sensor Magnelab Revenue Grade SCT-075H
100-1500 Aac input : 333 mVac output. 2" opening 400-3000 Aac input : 333 mVac output. 3"x5" opening 50-200 Aac input : 333 mVac output. 0.75" opening. +/- 0.5% linearity, phase angle +/- 0.25%
RCT-1200 Magnelab Current Sensor 333mV Output RCT-1200-000 Magnelab AC Current Sensor RCT-2400 Magnelab Current Sensor 333mV Output
250-5000 Aac input : 333 mVac output. 4" opening. Flexible 250-5000 Aac input : 70 mVac output for every 1000A. 4" diameter opening. Flexible 250-5000 Aac input : 333 mVac output. 8" opening. Flexible
RCT-3600 Magnelab 333mV Output AC Current Sensor RCS-1200 3-Phase Magnelab Current Sensor Output RCT-2400 Flexible Current Sensor 333mV Output
250-5000 Aac input : 333 mVac output. 12" opening. Flexible 3-Phase 250-5000 Aac input : 333 mVac output. 4" opening. Flexible
250-5000 Aac input : 70 mVac output for every 1000A input. 8" opening. Flexible
Magnelab 3-Phase RopeCT AC Current Sensor RCS-3600 3-Phase Magnelab Sensor 333mV Output Magnelab 3-Phase AC Current Transducer
3-Phase 250-5000 Aac input : 333 mVac output. 8" opening. Flexible 3-Phase 250-5000 Aac input : 333 mVac output. 12" opening. Flexible 3-Phase 250-5000 Aac input : 4-20 mA output. 4" opening. Flexible
Magnelab 3-Phase 4-20 mA AC Current Transducer Magnelab Solid-Core AC Current Sensor UCT-0300 Magnelab Solid-Core AC Current Sensor UCT-0500
3-Phase 250-5000 Aac input : 4-20 mA output. 8" opening. Flexible
5-30 Aac input : 333 mV output. 0.30" opening 10-60 Aac input : 333 mVac output. 0.5" opening